FUJIFILM Techno Products EMC Center

Minamiashigara-Shi, Kanagawa, Japan

Active Accreditation

FUJIFILM Techno Products EMC Center operates from Fujifilm's Minamiashigara site in Kanagawa, Japan, offering EMC emissions and immunity testing under ISO/IEC 17025 with NVLAP accreditation (lab code 200779). The facility features a 10-meter semi-anechoic chamber, a compact anechoic chamber, and two shielded rooms, with direct truck access for large equipment and a demonstrated track record testing medical, analytical, IT, and industrial products. It is an FCC-listed testing laboratory (JP5023) and a TUV Rheinland appointed site for witnessed testing.

DesignationJP5023
CountryJapan
CityMinamiashigara-Shi, Kanagawa
Accreditation StatusActive

Capabilities

Standards Tested

FCC Part 15CISPR 32EN 55032VCCIIEC 61000-3-2IEC 61000-3-3IEC 61000-4-2IEC 61000-4-3IEC 61000-4-4IEC 61000-4-5IEC 61000-4-6IEC 61000-4-8IEC 61000-4-11

Certifications Offered

FCCVCCI

Industries Served

Medical devicesAnalytical/scientific instrumentsIT equipmentIndustrial equipment

Facility

10m semi-anechoic chamber (15.0 x 23.0 x 9.0 m shielded, 5.0 m turntable, 3.0 ton capacity), compact anechoic chamber (5.0 x 9.0 x 4.0 m, 2.0 m turntable), and two shielded rooms (5.0 x 9.0 x 4.0 m each); 3.0 x 3.0 m EUT access for large equipment

Capabilities sourced from lab websites, A2LA scope documents, and public accreditation records as of April 23, 2026. Contact the lab directly to confirm current scope and availability.