Reliability Laboratory - New H3C Technologies Co.,

Hangzhou, Zhejiang, China

BannedActive Accreditation

FCC Recognition Withdrawn

This laboratory was banned from performing FCC compliance testing under FCC Rule 25-27, effective September 26, 2025. Test reports from this lab are no longer accepted by the FCC.

Reliability Laboratory of New H3C Technologies Co., Ltd. is the in-house EMC, radio, RF exposure, and product safety testing facility of New H3C Technologies, a major Chinese networking and IT infrastructure manufacturer based in Hangzhou. It holds A2LA accreditation under ISO/IEC 17025:2017 (Cert. No. 2608.01, valid to September 30, 2027) covering a broad scope of FCC, CE/RED, ISED, VCCI, and Chinese GB/YD standards, with a 3m semi-anechoic chamber for emissions testing up to 40 GHz. Its FCC test firm designation renewal was denied on September 26, 2025 as part of the FCC's enforcement actions against Chinese-controlled testing laboratories.

DesignationUS1176
CountryChina
CityHangzhou, Zhejiang
Accreditation StatusActive

Capabilities

Standards Tested

ANSI C63.4:2014ANSI C63.10:2013CISPR 11CISPR 22CISPR 24CISPR 32CISPR 35EN 55011EN 55022EN 55024EN 55032EN 55035IEC 61000-3-2IEC 61000-3-3IEC 61000-4-2IEC 61000-4-3IEC 61000-4-4IEC 61000-4-5IEC 61000-4-6IEC 61000-4-8IEC 61000-4-11IEC 61000-4-29IEC 61000-6-1IEC 61000-6-2IEC 61000-6-3IEC 61000-6-4IEC 61000-6-5IEC 61000-6-8IEC 60601-1-2IEC 61850-3IEC 62236-3-2IEC 62236-4IEC 62920ETSI EN 300 328ETSI EN 300 386ETSI EN 300 440ETSI EN 300 220-1ETSI EN 300 220-2ETSI EN 301 489ETSI EN 301 893ETSI EN 302 502ETSI EN 303 413ETSI EN 303 687EN 50121-3-2EN 50121-4EN 50130-4EN 50155RSS-GENRSS-247RSS-248VCCI V-3VCCI V-4VCCI-CISPR 32ICES-003GB/T 9254GB 4824GB 4943.1GB 17625.1IEC 60950-1UL 60950-1IEC 62368-1EN 62368-1UL 62368-1IEC 62311IEC 62479EN 50385MIC Notice No. 88 Appendix No. 43MIC Notice No. 88 Appendix No. 453GPP TS 38.113GR-1089-COREIEEE 1613

Certifications Offered

FCCISED CanadaCE / REDUKCAVCCIMIC / TELEC (Japan)CCC / SRRC (China)

Industries Served

Information Technology EquipmentTelecommunicationsNetworking EquipmentIndustrialCommercialResidentialMedical DevicesRailwayPower Systems

Facility

3m semi-anechoic chamber (emissions up to 40 GHz); EMC, radio, RF exposure, and product safety testing

Capabilities sourced from lab websites, A2LA scope documents, and public accreditation records as of April 23, 2026. Contact the lab directly to confirm current scope and availability.

Same country